There are four units of MAN diesel genset, but they are run on diesel fuel, not on HFO. I have to confirm whether they can operate on hfo,
Preliminary information:
Type: four units of MAN 18V40/45,10500V,600rpm, made in 1996, running 10000 hours, can be off load test.
14. And here we have more other units of Deuzt MWM and Mireels Blackstone sets JXPX
1. Three units of Deuzt MWM BV16M640,6350KW,10500V,600RPM, made in 90, running 60000 hours, can be tested off load, now operating on diesel oil not hfo.
2. Two units of Mirrlees Blackstone 16MB430,11300KW,600rpm, bore: 430mm,Piston stroke: 480mm,voltage: 10500V,Diesel engine weight:118tons, generator weight: 48tons, dimension: lengthxwidthxheight=7.73x3.82x4.73meters, including oil feeding system, lube system, air start system, distribution panels, but excluding cables, and transformer, currently running on diesel oil not on HFO.
15. Used MAN, Suzler, and other used HFO genset from CSDG
1.
Nine units of MAN B&W 18V 40/45, unit capacity: 10890KW, Speed: 600 r/min, Generator: Siemens 1DK5037-3DE05-Z, rated capacity: 13200KVA, voltage: 10500V, Current: 726A. Prodcued in 1993, operated 70,000 hours on HFO, and shutdown in Feb, 2007.
2. four units of MAN B&W 16V 40/45, unit capacity: 9340Kw, speed: 600 r/min, Generator: Siemens 1DK5037-3DE05-Z, rated capacity :11676KVA,Voltage: 11000V, Current: 613A. produced in 1985, operated on HFO for 30000 hours, dismantled in Oct. 2006, now stocked in stockroom.
3.Two units of Japan Nigata 18PC2-6/2, unit capacity: 9500KW, Speed: 500 r/min. Generator: TOYO DENKI, capacity: 11875KVA, voltage: 10500V, current:653A. produced in 1996, operated on HFO for 65000 hours, shutdown in March, 2007.
4. Two units of Sweden Sulzer 16ZAV40S, unit capacity: 11520KW, speed: 500 r/min. Generator: French GEC Alsthom, rated capacity: 14000KVA, voltage: 10509V, current: 770A. Produced in 1994, operated on HFO for 75000 hours. Shutdown in Dec. 2007
5.Four units of Sweden 16ZAV40S�?unit capacity: 11520KW, speed: 500 r/min. Generator: French GEC Alsthom, rated capacity: 14000KVA, voltage: 10509V, current: 770A. Produced in 1994, operated on HFO for 75000 hours. still in operation, but to be arranged for sale.
6. Two units of Sweden Sulzer 16ZAV40S, unit capacity: 11520KW, speed: 500 r/min. Generator: French GEC Alsthom, rated capacity: 14000KVA, voltage: 10509V, current: 770A. Produced in 1994, operated on HFO for 70000 hours. Shutdown in Dec. 2006.
7. Ten units of MAN B&W 18V 40/45, unit capacity: 10890KW. speed: 600 r/min. Generator: Siemens 1DK5037-3DE05-Z, rated capacity: 13200KVA, voltage: 10500V, curent: 726A. Produced in 1993, operated on HFO for 70000 hours. Shutdown in Feb. 2006.
8. Two units of mirrlees blackstone MB430VEI, unit capacity: 11683KW, speed: 600 r/min. Generator: Brush 37648A-1G, rate capacity: 14136KVA, voltage: 11000V, current: 742A. Frequency: 50HZ, complete auxiliaries. Produced in 1990, operated on HFO for 70000 hours.
9. Ten units of MAN B&W 9L 58/64, unit capacity: 11925KW, speed: 428 r/min. Generator: 1DK5928-3 DE 07-Z, rated capacity: 14500KVA, voltage: 11000V, current: 761A, frequency: 50HZ, complete auxiliaries. Produced in 1993, Operated on HFO for 50000 hours, all the main parts never replaced.
For more about our Heavy Fuel Oil (HFO) diesel generator power plants or generator sets, click.